Product Center
Your location:
Homepage
/
/
/
V cone flowmeter
Product category
Number of views:
1000

V cone flowmeter

Productname:v-coneflowmeterModel:LGV    Productintroduction:Thecharacteristicsoftraditionaldifferentialpressuremetersarebasedonidealflowconditions;infact,suchconditionsdonotexistinrealapplications.Anychangesinpipinglayout,suchaselbows,valves,reduceddiameters,enlargeddiameters,pumps,teejoints,etc.,willdestroythefullydevelopedflow.Itisdifficultforgeneralflowmeterstoobtaincorrectmeasurementvalues​​inturbulentflow.TheV-coneflowmeterovercomestheseshortcomings.Underextremelyharshinstallationconditions,iftherearetwoupstreamelbowsthatarenotonthesameplaneandareveryclosetothecone,theV-shapedconecanalsomakethespeeddistributionflatandsymmetric,thusensuringthemeasurementaccuracy.BecausetheorificeedgeoftheV-coneflowmeterisobtuse,theflow    Detailedintroduction:    Maintechnicalparameters1.Accuracygrade:0.5,1.0    2,workingpressure:≤16MPa    3,workingtemperature:-30-450℃    4.Ambienttemperature:-30-70℃    5.Pipeinnerdiameter:15-3000mm    6,outputsignal:4-20mA    7,powersupplyvoltage:24VDC    8.Applicablemedium:suitableforgasandliquidmedium.    NotesInstallation    ▲Itcanbeinstalledhorizontally,verticallyorobliquely,andthepipeshouldbefilledwithliquid.    ▲Thestraightpipesectionbeforeandafterthethrottlingdeviceshouldbestraight,withoutvisiblebending,andatthesametimeshouldbe"round",theinnerwallshouldbeclean,withoutpitsandsediment.    ▲Thepressurepipinginstallationshouldcomplywiththespecificationsstipulatedbythestandard.  downloadGoogle    Pleaseprovidethefollowingdataindetailwhenordering:    (1)Measuredmedium    (2)Large,common,smallflow.    (3)Workingpressure,workingtemperature    (4)Mediumdensityandviscosity    (5)Pipematerial,innerdiameter,outerdiameter    (6)Allowablepressureloss    (7)Pressuretakingmethod    (8)On-sitepipelineinstallationsituationandtheformoflocalresistanceparts.    ProductclassificationandstructureAccordingtothescopeofproductsupplyandtheoutputsignal,theV-coneflowmetercanbedividedinto3categories:    1.TheV-coneflowsensoronlyprovidestheformingpartofthedifferentialpressuresignal(throttlepartsandpipes),anddoesnotprovidethedifferentialpressuretransmitterandflowdisplaypart,andtheoutputsignalisdifferentialpressure.Itisuptotheusertomakeotherconfigurations.    2,V-coneflowtransmitter    consistsofaV-coneflowsensorandadifferentialpressuretransmitter.Therearetwostructures,splitinstallationandintegratedinstallation.    ThesplitV-coneflowtransmitteriscomposedofanindependentV-coneflowsensorandadifferentialpressuretransmitter.ThepressurepipeconnectionbetweentheV-coneflowsensorandthedifferentialpressuretransmitteriscompletedbytheuser.    IntegratedinstallationmeansthatthedifferentialpressuretransmitterandtheV-coneflowsensorhavebeenconnectedintoonewhentheproductleavesthefactory.AftertheuserpurchasestheintegratedV-coneflowtransmitter,thereisnoneedtoconnectthepressurepipewhenusingit.However,thecorrespondingflowtotalizer,pressuretransmitterandtemperaturetransmittermustbeconnected.    3,V-coneflowmeter    Therearetwostructuresofsplitinstallationandintegratedinstallation:    SplitinstallationiscomposedofindependentV-cone,differentialpressure,pressure,temperaturetransmitter,flowcalculator,stopvalveandotherparts.Theconnectioncombinationbetweenthevariouspartsiscompletedbytheuserhimself.Therearetwokindsofexplosion-prooftypeandordinarytype
Retail price
0.0
Market price
0.0
Number of views:
1000
Product serial number
Quantity
-
+
Stock:
0
Description
Parameters

  Product name: v-cone flowmeter

    Model: LGV

    Product introduction: The characteristics of traditional differential pressure meters are based on ideal flow conditions; in fact, such conditions do not exist in real applications. Any changes in piping layout, such as elbows, valves, reduced diameters, enlarged diameters, pumps, tee joints, etc., will destroy the fully developed flow. It is difficult for general flow meters to obtain correct measurement values ​​in turbulent flow. The V-cone flowmeter overcomes these shortcomings. Under extremely harsh installation conditions, if there are two upstream elbows that are not on the same plane and are very close to the cone, the V-shaped cone can also make the speed distribution flat and symmetric, thus ensuring the measurement accuracy. Because the orifice edge of the V-cone flowmeter is obtuse, the flow

    Detailed introduction:

    Main technical parameters 1. Accuracy grade: 0.5, 1.0

    2, working pressure: ≤16MPa

    3, working temperature: -30-450℃

    4. Ambient temperature: -30-70℃

    5. Pipe inner diameter: 15-3000mm

    6, output signal: 4-20mA

    7, power supply voltage: 24V DC

    8. Applicable medium: suitable for gas and liquid medium.

    Notes Installation

    ▲It can be installed horizontally, vertically or obliquely, and the pipe should be filled with liquid.

    ▲The straight pipe section before and after the throttling device should be straight, without visible bending, and at the same time should be "round", the inner wall should be clean, without pits and sediment.

    ▲The pressure piping installation should comply with the specifications stipulated by the standard.

  download Google

    Please provide the following data in detail when ordering:

    (1) Measured medium

    (2) Large, common, small flow.

    (3) Working pressure, working temperature

    (4) Medium density and viscosity

    (5) Pipe material, inner diameter, outer diameter

    (6) Allowable pressure loss

    (7) Pressure taking method

    (8) On-site pipeline installation situation and the form of local resistance parts.

    Product classification and structure According to the scope of product supply and the output signal, the V-cone flowmeter can be divided into 3 categories:

    1. The V-cone flow sensor only provides the forming part of the differential pressure signal (throttle parts and pipes), and does not provide the differential pressure transmitter and flow display part, and the output signal is differential pressure. It is up to the user to make other configurations.

    2, V-cone flow transmitter

     consists of a V-cone flow sensor and a differential pressure transmitter. There are two structures, split installation and integrated installation.

    The split V-cone flow transmitter is composed of an independent V-cone flow sensor and a differential pressure transmitter. The pressure pipe connection between the V-cone flow sensor and the differential pressure transmitter is completed by the user.

    Integrated installation means that the differential pressure transmitter and the V-cone flow sensor have been connected into one when the product leaves the factory. After the user purchases the integrated V-cone flow transmitter, there is no need to connect the pressure pipe when using it. However, the corresponding flow totalizer, pressure transmitter and temperature transmitter must be connected.

    3, V-cone flowmeter

    There are two structures of split installation and integrated installation:

     Split installation is composed of independent V-cone, differential pressure, pressure, temperature transmitter, flow calculator, stop valve and other parts. The connection combination between the various parts is completed by the user himself. There are two kinds of explosion-proof type and ordinary type

Keyword:
V cone flowmeter
We could not find any corresponding parameters, please add them to the properties table

Related Products

1
 Integrated electromagnetic flowmeter
Integrated electromagnetic flowmeter
Product introduction: HHLD electromagnetic flowmeter is an induction meter that measures the volume flow of conductive medium in the tube according to Faraday's law of electromagnetic induction.
 Plug-in electromagnetic flowmeter
Plug-in electromagnetic flowmeter
The measurement principle of the plug-in electromagnetic flowmeter is Faraday's law of electromagnetic induction.
 Battery-powered electromagnetic flowmeter
Battery-powered electromagnetic flowmeter
The battery-powered electromagnetic flowmeter uses a 16-bit embedded ultra-micro power consumption microprocessor and a sensor excitation system designed with special technology.
 Clamp-connected electromagnetic flowmeter
Clamp-connected electromagnetic flowmeter
Product introduction: HHLD electromagnetic flowmeter is an induction meter that measures the volume flow of conductive medium in the tube according to Faraday's law of electromagnetic induction.

Online Inquiry

Product information

Product serial number
Thumbnail
Name of product
Retail price
Expected unit price
*Order quantity
Operation
Product serial number:
$formItem.imageUrl
V cone flowmeter
Retail price: 0.0
* Expected unit price
*Order quantity
-+
Remove

Contact information

Basic information
Method of contact and profession
Company information
Verification Code

Add product X

Product categories:
All products
Selected 0 Each
搜索

Navigation

Copyright © 2021 Kaifeng Henghe Flow Meter Co., Ltd.                Powered by www.300.cn        This website already supports IPv6

Copyright  © 2021 Kaifeng Henghe Flow Meter Co., Ltd.

Powered by www.300.cn
This website already supports IPv6